How do you size a dryer for your air compressor? Some air compressor systems include an air treatment package built-in. For those that don’t – you can select from a desiccant filter/dryer unit, or cycling and non-cycling refrigerated air dryers. It is not complicated, but at the same time there are a few thumb-rules that come into consideration.
Ambient Temperature, Inlet Temperature, and Pressure must be considered.
Most often, you can assume 100°F Ambient Temperature, 100°F Inlet Temperature to the Dryer (aka discharge of the compressor), and 100psi.
If your air compressor can put out 50cfm, you need at least 50 cfm of capacity in your air dryer. It is important to note that your dryer is then already at max capacity. Those key factors like high ambient temperature will reduce the capacity of your dryer, depending on how much drying capability is required. It should make sense – if you are running equipment during the hot and humid month of August in a place like Florida, your dryer is going to be pulling gallons upon gallons of condensate out of that air. If your dryer is undersized, your air will be out of spec and you will be sending water down your discharge piping!
It is common practice to run a dryer that has a capacity 15-30 cfm higher than your compressor.
Don’t forget to install an Oil / Water Separator to easily remove oil from discharged condensate right at the source! Otherwise, it is against local and federal regulation to discharge oily water down the drain, and costly to contract out the treatment of thousands of gallons of oily water..
All compressed air dryers have a maximum drying capacity expressed in cubic feet per minute (cfm). So to make sure your compressed air system has enough drying capacity, all you need to do is get a dryer with a rated cfm higher than your air compressor’s output cfm and that can handle the compressor’s output pressure, and you’re set, right?
Not quite. That cfm rating on your dryer represents SCFM, not ACFM, and ACFM is what you really care about.
SCFM? ACFM? What’s the difference? And why does it matter anyway?
SCFM is the rated capacity of the dryer under standard conditions. While these can vary between countries and even manufacturers, the standard conditions used by Sullair (and in the United States generally) for dryers are:
ACFM is the maximum air flow the dryer can effectively dry after adjusting for actual operating conditions. Whenever your operating conditions don’t match the standard conditions, the ACFM of the dryer will not match the SCFM.
You always want to use ACFM. Why? ACFM adjusts for the environmental factors in your compressor room or other installation site that affect compressed air dryer performance.
SCFM doesn’t account for those factors. Unless your operating conditions exactly match standard conditions, you’ll be undersizing or oversizing your dryer if you use SCFM. (We’ll cover the problems with both of those later.)
Inlet air pressure and drying capacity are directly related. The higher the inlet air pressure, the higher the drying capacity, and vice versa.
Air moves more slowly as air pressure increases. Slower air movement means more contact time with either the heat exchanger (in a refrigerated air dryer) or the desiccant beads (in a desiccant dryer). The longer contact time increases dryer efficiency. Conversely, faster air means less contact time and decreases dryer efficiency.
Inlet air temperature and drying capacity are inversely related. The higher the inlet air temperature, the lower the drying capacity, and vice versa.
Warmer air holds more water vapor than cooler air, so the dryer has to remove more moisture in the same amount of time, making it less efficient.
Ambient air temperature and drying capacity are inversely related. The higher the inlet air temperature, the lower the drying capacity, and vice versa. but only for refrigerated dryers, at least directly.
As the ambient air temperature increases, the refrigerated dryer dissipates heat less efficiently, effectively reducing dryer capacity. Conversely, in cooler environments, dryer capacity is effectively increased because it can dissipate heat more efficiently.
The vast majority of applications don’t have to adjust for relative humidity. Why not? Because under most ambient conditions, the air will be at 100% relative humidity once it reaches the dryer.
During compression, the air will typically reach 80 to 90% relative humidity at a high temperature (75°+ above ambient). After the air passes through the aftercooler, though, the temperature will drop to within 10 to 15° of ambient and become fully saturated at 100% relative humidity. (Remember, cooler air can hold less water vapor than warmer air.) Some moisture will even drop out as liquid water during the cooling process.
When sizing dryers, you want to be as close as you can to the size you need under worst-case conditions without going under. Why? Because the marginal costs of “sizing up” slightly, even for desiccant dryers, are relatively small compared to the ultimate potential costs of undersizing.
True, oversizing adds excess capacity and can increase capital, operating, and maintenance costs. For refrigerated dryers, it can also lead to shorter equipment life due to additional stress on the controls. But these costs can be planned for up front. And by keeping oversizing to a minimum, you can keep the cost to a minimum, too.
The effects of undersizing, however, cannot be planned for and minimized up front. Why? Because undersizing creates reduced drying capacity. The result? You won’t meet the level of dryness (the pressure dew point) your process, application, or equipment needs. This could lead to equipment damage or failure. In some cases, it could even lead to an unusable end product, with botched work products (for example, a ruined paint job) or entire production runs wasted.
Air compressors can also be affected by actual conditions that can change their output flow and pressure. In addition, filters between the compressor and dryer can create pressure drop.
When using correction factors (see the next section), make sure you use the output pressure of the compressor after adjustments for actual conditions as well as drops caused by filters.
Compressed air dryers have correction factors to take into account actual conditions so dryers can be sized correctly. (The correction factors are usually given in the dryer literature). If your conditions can vary, use the correction factors for the worst set of conditions your system will face.
The formulas used for calculating ACFM are:
Once you have the dryer’s ACFM for your worst-case scenario, compare that to the inlet cubic feet per minute (ICFM) coming into the dryer. If the dryer’s ACFM is higher than the ICFM, the dryer has enough capacity to meet your needs.
You need to dry 458 ICFM. After filtration, under worst-case conditions the inlet pressure will be 140 psig, the inlet temperature will be 110°F, the ambient temperature will be 105°F, and the relative humidity will be 80%.
Would a Sullair SR+ 500 meet your needs?
Applying the correction factors for a SR+ 500 to the formula given above for refrigerated dryers, we get:
435 ACFM is smaller than 458 ICFM, so the SR+ 500 will not have enough capacity for your application.
Would a Sullair DEX‑500 meet your needs?
Applying the correction factors for a DEX‑500 to the formula given above for desiccant dryers, we get:
499 ACFM is larger than 458 ICFM, so the DEX‑500 will have enough capacity for your application.
If you’re not comfortable sizing dryers yourself, you should consult an expert to help you size them. Their years of experience configuring compressed air systems across a wide variety of applications can help ensure that you get the most economical drying solution that meets your needs.